ePS LAN Enabled Power Switch
Operation Manual Ver 1.0 04-03-09
General Description
The ePS is a single AC power switcher with an embedded web server
to provide IP control of the unit.
Features
Remote Control - Output can be switched on or off via the embedded web server.
Power Cycling - Output can be cycled (switched off for 5 seconds, then power switched back on)
Output Monitoring - Front panel and web monitoring of status of output and fuse.
Email Alerts - ePS can be programmed to send email alerts on detection of a fuse failur and power up.
Front Panel LED Output Indication
LED On - Output OK
LED Off - Output remotely switched off
LED Flash - Output switched on, but fuse failed
Software Setup
The ePS is supplied with an IP address of 192.168.0.209. This
address is in the space reserved for private networks.
If your PC is configured to respond to different IP addresses
based to its own IP address and mask settings, then the ePS will
not be recognized over the network connection by your PC.
You can change the IP address of the ePS via its serial port.
1
2 RS232 Tx
3 RS232 Rx
4
5 0v
6
7
8
9
Connect the ePS master to a host PC using the serial port,
configure a terminal program (e.g. Windows Hyper Terminal) with
the following settings:
Baud rate: 9600
Data: 8 bit
Parity: none
Stop: 1 bit
Flow control: none
On power up the status of the unit will be displayed:
IAM:Got AUTO-CONFIGURED IPv6 address FE80::240:9DFF:FE43:3597 on
interface eth03
IAM:Got STATIC IPv4 address 10.0.0.100 on interface eth0
Network IP configured.
Audionics - ePS AC Power Switcher
Initialising
FTP server started.
HTTP server started.
Initialised
System Info:
Software Version: 619R1047
MAC Address: 00:40:9D:43:35:97
IP Address: 192.168.0.209
Subnet Mask: 255.255.255.0
Gateway: 192.168.0.1
Port: 5000
SMTP Server: 192.168.0.1
Email To: eps@audionics.co.uk
Email Cc:
Send Cold Boot Email: No
Send Fuse Alert Email: No
Unit Name: ePS 1
Cycle Delay(secs): 5
PCAlive Enabled: No
Ping Address: 192.168.0.1
Ping Interval (secs): 10
Fails Before Reboot: 6
Restart Delay(secs): 120
Output State: On
Fuse State: OK
>
Once the ePS has fully initialized the command prompt will
appear. This information can also be shown at anytime by the
status command:
Status Command
>status
System Info:
Software Version: 619R1047
MAC Address: 00:40:9D:43:35:97
IP Address: 192.168.0.209
Subnet Mask: 255.255.255.0
Gateway: 192.168.0.1
Port: 5000
SMTP Server: 192.168.0.1
Email To: eps@audionics.co.uk
Email Cc:
Send Cold Boot Email: No
Send Fuse Alert Email: No
Unit Name: ePS 1
Cycle Delay(secs): 5
PCAlive Enabled: No
Ping Address: 192.168.0.1
Ping Interval (secs): 10
Fails Before Reboot: 6
Restart Delay(secs): 120
Output State: On
Fuse State: OK
>
Config Command
The configuration of the unit can be altered using the config
command, which will show the current configuration and enable the
user to change the configuration.
>config
IP Address: 192.168.0.209
Subnet Mask: 255.255.255.0
Gateway: 192.168.0.209
Change Settings? - y [n] -y
IP - 192.168.0.209 - New Value [No Change] -10.0.0.101
Subnet Mask - 255.255.255.0 - New Value [No Change] -
Gateway - 192.168.0.1 - New Value [No Change] 10.0.0.1
Port - 5000 - New Value [No Change] -
Reconfiguring Unit
Configuration Updated - Please Repower Unit
In order for the new configuration to take effect the unit needs to be repowered
User Command
The web browser and telnet interface are protected by a user name
and password. The default user name is eps and the default
password is password
To change the user name type user at the command prompt
>user
User Name Update
Current User Name - eps
New User Name (Max 15 Characters) - fred
Repeat New User Name - fred
Updating User Name
User Name Updated
>
Password Command
The change the user password type password at the command prompt
>password
Password Update
Current Password - password
New Password (Max 15 Characters) - secret
Repeat Password - secret
Updating Password
Password Updated
>
Output Control
The output can be switched on, off or cycled via the serial port
by using the output command.
>output off
Output has been switched Off
>
>output on
Output has been switched On
>
>output cycle
Output is being cycled
>
Web Browser Control
Logging On
When you log onto the IP address of the ePS the unit requests the
user name and password.
The ePS is supplied with the username as eps and password as
password, these can be changed via the serial port.
Main Display Page
Once logged on the main page is displayed:
The display page is updated every 5 seconds.
The ePS can be switched on, off or cycled by clicking on the
appropiate box.
To update the ePS details click on config.
ePS Configuration Page
Software Version Current software version number (non
configurable)
MAC Address - MAC address of LAN module (non configurable)
*IP Address IP adress of unit
*Subnet Mask Network subnet mask
*Gateway Network gateway address
*Port Port number for socket control (must not be 23)
SMTP Server Mail server (in dotted notation)
Email To Email address to send fuse and cold starts to
(max 47 characters)
Email Cc Email address to send fuse and cold starts to
(max 47 characters)
Email Subject Text to be displayed in email subject field
(max 31 characters)
Send Cold Start Email If checked on power up an email is
sent
Send Fuse Fail Email If checked on fuse fail or fuse
restore an email is sent
Unit Name The ePS name, displayed on web pages and in
emails
Cycle Delay Number of seconds that the unit will be
switched off during a power cycle (max 30 secs)
PCAlive Enable If checked the ePS will ping an IP address
to check it is alive, if no response after a number of attempts
the power will be cycled to reboot the device
Ping Address IP address for PCAlive to ping
Ping Interval Interval between pings (max 60 secs)
Fails Before Restart Number of unsuccessful pings before
power is cycled (max 10)
Restart Delay Delay before pings are restarted to enable
the monitored device to power up (max 300 secs), this delay is
also used on ePS power up before PCAlive starts.
*If these paramaters are changed a reboot is needed for them to
take effect
Firmware Update Page
Firmware upgrades may become available from time to time, these
will be made available on the Audionics website.
To upgrade the firmware, download image.bin from the website and
save to your local drive, click on browse to locate file
Select the image.bin file and click Open
Then click Upload.
A message will be displayed saying upload is in progress
DO NOT SWITCH OFF POWER DURING UPLOAD
When the new image file is loaded the following screen will be
displayed. The unit needs rebooting by either the web browser or
repowering the unit.
ePS Control Via LAN
Socket Connection
The ePS can also be controlled and monitored via the LAN
connection, by opening a socket on port 5000. Only one socket is
available, the socket should be opened, the command sent then the
socket closed to ensure that the socket is not left engaged.
Request Output State
For an output status request the connected client must send a
wake up to the ePS which is 0xFF and then a control code which in
this case is set to 0x01. The ePS will respond with an
acknowledgement of 0xFE, and an echo of the control code. It will
then send 1 byte of information for units output state.
Command
FFh Wake Up Server
01h Control Code Output status req
Response
FEh Acknowledge
01h Control Code
Byte 1 Output 00=on 01=off 02=fuse fail
Operate Output
To switch an output a wake up code and a control code must be
sent as before with the control code this time set to 0x02. Then
a byte must be sent to describe to the unit how to switch the
output 0x00 off, 0x01 on, 0x02 - cycle. The eMu
will again acknowledge and echo the control code.
Command
FFh Wake Up Server
02h Control Code Operate output
[state] - 1 = Switch Output On
0 = Switch Output Off
2 = Cycle Output
Response
FEh Acknowledge
02h Control Code
Revision History
V1.0 040309 Original PM